Loading...

Kolumny HPLC

Nazwa (kliknij po więcej infromacji) Opis
ProteCol™ C18 GP If you don’t need metal free column hardware, then the ProteCol™ GP HPLC column range is a robust, reliable alternative.
Particle
[µm]
Średnica(ID)
[mm]
Długość
[mm]
Pory
[Å]
Osłona Faza Opis Nr katalogowy
5 4.6 250 120 SS (PEEK™ frit) C18 GP Kolumna analityczna 250210
5 4.6 150 120 SS (PEEK™ frit) C18 GP Kolumna analityczna 250212
5 2.1 250 120 SS (PEEK™ frit) C18 GP Kolumna analityczna 250215
5 2.1 150 120 SS (PEEK™ frit) C18 GP Kolumna analityczna 250217
ProteCol™-G C18 HQ203 and HQ303 for peptides ProteCol™-G C18 HQ203 and HQ 303 are columns packed with stationary phases of 200Å and 300Å pores, respectively. They both show reasonably fast diffusion rates for a typical peptide (MW~5000) or any other molecule of a similar size.
The difference between them is the specific surface area (surface area are per unit of weight) which in case of the 200Å pore size material is twice as high as for the 300Å pore size particles (200 and 100 m²/g respectively). The surface area is directly linked to the column capacity. Resolution and peak capacity both columns provide very similar results.
Particle
[µm]
Średnica(ID)
[mm]
Długość
[mm]
Pory
[Å]
Osłona Faza Opis Nr katalogowy
5 4.6 250 300 GLT™ C18 HQ Kolumna analityczna 250120
5 4.6 150 300 GLT™ C18 HQ Kolumna analityczna 250122
5 2.1 250 300 GLT™ C18 HQ Kolumna analityczna 250125
5 2.1 150 300 GLT™ C18 HQ Kolumna analityczna 250127
3 2.1 150 300 GLT™ C18 HQ Kolumna analityczna 250130
3 2.1 100 300 GLT™ C18 HQ Kolumna analityczna 250132
3 0.3 150 300 PEEKsil™ C18 HQ Kolumna kapilarna 250135
3 0.3 100 300 PEEKsil™ C18 HQ Kolumna kapilarna 250137
3 0.15 150 300 PEEKsil™ C18 HQ Kolumna kapilarna 250140
3 0.15 100 300 PEEKsil™ C18 HQ Kolumna kapilarna 250142
3 2.1 150 200 GLT™ C18 HQ Kolumna analityczna 250150
3 2.1 100 200 GLT™ C18 HQ Kolumna analityczna 250152
3 0.3 150 200 PEEKsil™ C18 HQ Kolumna kapilarna 250155
3 0.3 100 200 PEEKsil™ C18 HQ Kolumna kapilarna 250157
3 0.15 150 200 PEEKsil™ C18 HQ Kolumna kapilarna 250160
3 0.15 100 200 PEEKsil™ C18 HQ Kolumna kapilarna 250162
ProteCol™-G C8 HQ1003 for proteins ProteCol™-G C8 HQ1003 – The protein separation column.
Since a 300Å pore size is not ideal for separating larger proteins, ProteCol™-G C8 HQ1003 column therefore uses a 1000Å pore size packing material.
Most proteins have a very hydrophobic core and they tend to unfold when coming in contact with a reversed phase surface. This can lead to very strong binding and sample loss. A C8 stationary phase gives much higher recoveries.
Particle
[µm]
Średnica(ID)
[mm]
Długość
[mm]
Pory
[Å]
Osłona Faza Opis Nr katalogowy
3 2.1 150 1000 GLT™ C8 HQ Kolumna analityczna 250170
3 2.1 100 1000 GLT™ C8 HQ Kolumna analityczna 250172
3 0.3 150 1000 PEEKsil™ C8 HQ Kolumna kapilarna 250175
3 0.3 100 1000 PEEKsil™ C8 HQ Kolumna kapilarna 250177
3 0.15 150 1000 PEEKsil™ C8 HQ Kolumna kapilarna 250180
3 0.15 100 1000 PEEKsil™ C8 HQ Kolumna kapilarna 250182
ProteCol™-G C8 HQ125
Particle
[µm]
Średnica(ID)
[mm]
Długość
[mm]
Pory
[Å]
Osłona Faza Opis Nr katalogowy
5 4.6 250 120 GLT™ C8 HQ Kolumna analityczna 250190
5 4.6 150 120 GLT™ C8 HQ Kolumna analityczna 250192
5 2.1 250 120 GLT™ C8 HQ Kolumna analityczna 250195
5 2.1 150 120 GLT™ C8 HQ Kolumna analityczna 250197
ProteCol™-P C18 HPH125 for High pH The ProteCol™-P C18 HPH125 column has a specially modified stationary phase which allows it to be used outside commonly recommended pH ranges. While the silica matrix material of any silica based HPLC column has a stability limit of ~pH8, the special C18 modification of the support in combination with the PEEK™-lined column hardware enables the column to be run at pH9 and above without deterioration of performance.

Particle
[µm]
Średnica(ID)
[mm]
Długość
[mm]
Pory
[Å]
Osłona Faza Opis Nr katalogowy
5 4.6 250 120 PEEK™ lined C18 HPH Kolumna analityczna 250110
5 4.6 150 120 PEEK™ lined C18 HPH Kolumna analityczna 250112
5 2.1 250 120 PEEK™ lined C18 HPH Kolumna analityczna 250115
5 2.1 150 120 PEEK™ lined C18 HPH Kolumna analityczna 250117
ProteCol™-P C18 HQ100 extreme inertness Premium phase for optimal performance
SGE’s inert HPLC column range enables you to focus on your application rather than the column’s performance. The NIST SRM870 method is designed to provide an even bench mark for C18 column performance. ProteCol™-P C18 HQ105 approaches the ’ideal’ performance of a column with no non-specific interactions.
Particle
[µm]
Średnica(ID)
[mm]
Długość
[mm]
Pory
[Å]
Osłona Faza Opis Nr katalogowy
5 4.6 250 100 PEEK™ lined C18 HQ Kolumna analityczna 250100
5 4.6 150 100 PEEK™ lined C18 HQ Kolumna analityczna 250102
5 2.1 250 100 PEEK™ lined C18 HQ Kolumna analityczna 250105
5 2.1 150 100 PEEK™ lined C18 HQ Kolumna analityczna 250107
3 2.1 150 100 PEEK™ lined C18 HQ Kolumna analityczna 250200
3 2.1 100 100 PEEK™ lined C18 HQ Kolumna analityczna 250202